SPECIFICATIONS
Hign-concerned Chemical: None
MANUFACTURE: CONTEC MEDICAL SYSTEMS CO.,LTD
Model Number: Patient Monitor-Sleep Apnea Screen Meter-RS01
1.8" OLED display screen
Convenient operation
Wrist-design,tiny and light
Multiple functions in one device,supplying more vital information
SpO2 and pulse rate(hereinafter referred to as "PR") value display
Pulse sound and indicator bar
Pulse and nose flow waveform display
Such alarms as low power, finger out and exceeding limits can be set up
The degree for screen back-light is adjustable
Real-time clock
Auto-power on/off
Multi-case record
Continuous 20 hours data record
Uploading Data via USB port
Powerful PC analysis software
Performance parameters
(1) Nose air flow measurement:
Measurement range:0rpm~40rpm
Resolution:1rpm
Accuracy:±2rpm
(2) SpO2 measurement:
Measurement range:0%~100%
Resolution:1%
Accuracy: 70%~100% ,±2% ;<70% unspecified
(3) Pulse rate measurement:
Measurement range:30bpm~250bpm
Resolution:1bpm
Accuracy: ±2 bpm and ±2%(selecting larger)
(4) Measurement Performance in Weak Filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (selecting larger).
(5)Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Specification
Power Supply : ONE 3.7V Lithium Battery
Display : 1.8" color OLED
Dimension:69mm(L)× 50mm(W)×17.3mm (H)
Respiration Sleep Monitor Spo2,Pulse Rate,Nose Air Flow Measure
Main Features
1.8" OLED display screen
Convenient operation
Wrist-design,tiny and light
Multiple functions in one device,supplying more vital information
SpO2 and pulse rate(hereinafter referred to as "PR") value display
Pulse sound and indicator bar
Pulse and nose flow waveform display
Such alarms as low power, finger out and exceeding limits can be set up
The degree for screen back-light is adjustable
Real-time clock
Auto-power on/off
Multi-case record
Continuous 20 hours data record
Uploading Data via USB port
Powerful PC analysis software
Performance parameters
(1) Nose air flow measurement:
Measurement range:0rpm~40rpm
Resolution:1rpm
Accuracy:±2rpm
(2) SpO2 measurement:
Measurement range:0%~100%
Resolution:1%
Accuracy: 70%~100% ,±2% ;<70% unspecified
(3) Pulse rate measurement:
Measurement range:30bpm~250bpm
Resolution:1bpm
Accuracy: ±2 bpm and ±2%(selecting larger)
(4) Measurement Performance in Weak Filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (selecting larger).
(5)Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Specification
Power Supply : ONE 3.7V Lithium Battery
Display : 1.8" color OLED
Dimension:69mm(L)× 50mm(W)×17.3mm (H)
Share